AEG washer dryer – L77685 = No heat on dry

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries AEG washer dryer – L77685 = No heat on dry

Viewing 8 posts - 1 through 8 (of 8 total)
  • Author
    Posts
  • #101511
    asp11
    Participant

    This doesn’t have any reset TOC….. It goes onto the heat setting but the fan motor doesn’t start and nor do the heaters but it pumps out during the heat cycle fine and is quiet when it should have the motor/heater in operation and there’s no clicking or sounds from the boards – Not drawing any amps inbetween the pump outs (just silent)

    I’m confused as to why the pump works when it should during a dry cycle but not the dryer motor or heaters AND No error codes??

    PCN : 914605802-00
    SER : 30900013

    #485022
    electrofix
    Moderator

    uhave you gone into service mode and looked for error codes ?

    have you checked water solenoid. Often these machines do a water check before starting dryer properly

    Dave

    #485023
    asp11
    Participant

    electrofix wrote: uhave you gone into service mode and looked for error codes ?

    have you checked water solenoid. Often these machines do a water check before starting dryer properly

    Dave

    I don’t know how to put it into Service mode unfortunately and didn’t know about the vavle check – it washes all ok though?
    Is there a test mode on here somewhere, it didn’t come up when I entered the model number?

    #485024
    electrofix
    Moderator

    have sent you the service info

    Dave

    #485025
    asp11
    Participant

    electrofix wrote:have sent you the service info

    Dave

    THANKS Dave — I went back today and it did show up an error of = ed1
    which is a communication failure between the boards….. the suggestion in the manual says to change the “WD satallite board” but I find that in the any part description, do they mean the dryer board or the main board… or are there more boards??

    #485026
    electrofix
    Moderator

    i assume they mean the dryer board

    might be part no 132 78 73-00 / 4

    listed as £86 retail

    https://shop.aeg.co.uk/search?q={e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d}3Ar…=3&pagesize=20

    have you check wiring and removed and replaced connectors ?

    dont forget with a communication problem it can be either board or both

    Dave

    #485027
    asp11
    Participant

    Yes I’ve checked the wiring going to the dryer board and my research shows the same part number, so I’ll quote the customer and see what happens….. THANKS again Dave for your incredible knowledge Happy New Year!

    #485028
    asp11
    Participant

    Just to confirm and help any future engineers — The dryer Pcb did solve the problem……. Ta Dave!

Viewing 8 posts - 1 through 8 (of 8 total)