I have Beko DCY7402GXB2 dryer and its not heating at all otherwise operating normally. I checked thermostat on heater and its good and the NTC is reading 1Kohm and resistance lowers when i raise temp, the NTC on door is reading much higher though 20Kohm. Is the rear reading too low? the part number on rear NTC says 2971900100
Yes it’s 7182482930
Also I got into service mode and although I dont have service manual I could see it gave NTC readings NT:01 13 NT:02 92, it then did dr:rr drum test then it got to hu:nd and gave error 5c:Er and wouldn’t continue.
I realised the NT readings are the temps and NT02 is obvoiusly way out. I confirmed with 20k resistor instead of the NTC and dryer started heating again