Zanussi DW907 heating element ?

Home Forums Public Support Forums Help And Support Dishwasher Help Forum Zanussi DW907 heating element ?

Viewing 8 posts - 1 through 8 (of 8 total)
  • Author
    Posts
  • #102005
    tonyb61
    Participant

    I’m not having much luck finding a replacement heating element for a Zanussi DW907 dishwasher. Does anyone know a good source for this part ?
    thanks
    Tony

    #487127
    electrofix
    Moderator

    1 has it gone, have you tested it ?

    2 let me have the pnc number as i get 8 hits for that model

    it over 23 years old so we may struggle

    Dave

    #487128
    electrofix
    Moderator

    doing a random search on one of them i get this one

    https://shop.ukwhitegoods.co.uk/d355419-compatible-dishwasher-heating-element

    but you need to check its correct

    Dave

    #487129
    tonyb61
    Participant

    Hi, sorry for delay in replying.
    The numbers on the dw are
    Product no 91181036
    Type 91181-1A
    The main reason to suspect the element is the machine is not heating up and is cold at the end of a cycle.
    Today I did a quick check on the element and it is not open circuit, though i didn’t have my ohmmeter handy to check actual resistance. I’ll do that later this week. But maybe not that then. I presume there is a thermostat that measures water temp to cut off the heater when temp has been reached, so this could be faulty ?
    Regards
    Tony

    #487130
    electrofix
    Moderator

    ok if the element is ok

    you need to check both thermostats
    then the wiring from the timer

    if all that is ok its most likley a timer contact failure

    Dave

    #487131
    tonyb61
    Participant

    Hi Dave,
    I popped around and measured the element at 21.9 ohms which looks about correct for a 2.5kW element.
    BTW the pnc I quoted above was missing a digit it’s 91186103600.

    I took out the thermostat that is clipped to the steel bottom of the dishwasher washing chamber next to the heating element, and that shows a short at room temp, and opens if I put the metal case in hot water so that looks to be working fine. I couldn’t spot a second thermostat though ? Where might this be ?

    Regards
    Tony

    #487132
    electrofix
    Moderator

    looks like the other stat is in the door

    Dave

    #487133
    tonyb61
    Participant

    Hi Dave,
    As you predicted the other thermostat was in the door. I removed this, tested it and that worked too. So I put everything back together and decided to try the dw out, and it seems to be working fine now. I’ve got no explanation for that unless there was a dodgy contact that is now working. We’ll keep an eye on it and see how it goes.
    Thanks for the tips !
    Regards
    Tony

Viewing 8 posts - 1 through 8 (of 8 total)