Siemens WM12B180GB/07 (Extra Klasse)

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Siemens WM12B180GB/07 (Extra Klasse)

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #102202
    rocker
    Participant

    I am unable to reset this machine and clear the error code..after fitted a new interlock…tried a few I knew and some on you tube …none worked.. any advice welcome. this appears to be a cheaper version machine..?? John

    #487924
    electrofix
    Moderator

    normally there is no reset after a door lock

    what fault are you getting

    what resets have you tried ?

    Dave

    #487925
    rocker
    Participant

    Hi Dave, E16 .. turn to 6 0 clock hold in spin for 5 seconds release turn to 12 o clock

    #487926
    electrofix
    Moderator

    are you still getting E16

    this is the older type heater lock. have you checked board for damage ?

    Dave

    #487927
    rocker
    Participant

    No I haven’t yet but I will do now…thanks for your advice..

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.