    WhiteVanMan1
    Participant

    The machine starts, fills and agitates ok. After about eight minutes, the super wash, slow spin, time saver, and eco wash led’s start flashing and it goes into pump out mode. I’ve checked all heaters, all ok. I’m suspecting a control module heater circuit fault. Any ideas please? Also, I I’ve looked at modules just in case, but it seems they only come unprogrammed. Any assistance greatly appreciated thank you. Steve.

    #490267
    electrofix
    Moderator

    fault code on these will be the vertical lights on the right

    from the bottom which ones are lit and not lit

    Dave

    normally the lights are binary so first light is worth 1 when lit , the next 2 followed by 4, 8 and 16 you add these up to get code

    #490268
    WhiteVanMan1
    Participant

    Thank you for your reply Electrofix. Only light illuminated on the vertical bank is the door locked light. The four horizontal lights are flashing.

    #490269
    electrofix
    Moderator

    ok that look like poss fault 1

    fault 1 is motor triac problem but earth leakage on the motor has been known to cause this on some machines

    could be as simple as carbon dust also chech for small leaks onto motor

    Dave

    #490270
    WhiteVanMan1
    Participant

    Cheers Dave. Motor is brushless and works fine. It seems to get to heat pause, then go into fault mode. At the moment she’s waiting until it goes into fault mode, then restarting on the rinse and spin programme to finish the wash, which it does without a problem. Steve.

    #490271
    electrofix
    Moderator

    F01 is one of those aweful codes with many problems

    this is not your machine but will give you ideas

    have not got manual for your model

    Dave

    #490272
    WhiteVanMan1
    Participant

    Thank you for that Dave, it’s very much appreciated. I think in light of all the facts, I’m certain in my mind that the fault lies in the PCB. My problem now is that the only PCB’s I can find are all unconfigured. Looks like a I recommend a call to Hotpoint . Thank you for your help. Steve.

    #490273
    electrofix
    Moderator

    just for your ref

    Aswo can supply configured boards

    Dave

    #490274
    WhiteVanMan1
    Participant

    Cheers Dave. Not used them before but will give them a try. Thank you so much for your help.
    Steve.

    #490275
    electrofix
    Moderator

    Aswo are brilliant
    stock is excellent and even has triacs relays and lots of electronic components , memory pens etc

    lots of helpful tech really really good on vestel machines

    Dave

    #490276
    WhiteVanMan1
    Participant

    Cheers Dave. Much appreciated

Viewing 11 posts - 1 through 11 (of 11 total)