F&P GW709AU

Viewing 15 posts - 1 through 15 (of 29 total)
  • Author
    Posts
  • #11023
    admin
    Keymaster

    Hi,

    My GW709AU will not begin a wash. I entered the diag mode(after reading around the forum to find out how) and received the following error lights:-

    00110010

    Any chance someone could email further diagnostics info to me at falcc41@hotmail.com ??

    Thanks!

    Falc.

    #143630

    Re: F&P GW709AU

    The hot valve is faulty, P/N 420148p .

    #143631
    admin
    Keymaster

    Re: F&P GW709AU

    Will this valve fault stop even a cold cycle wash? The machine doesn’t begin to fill with any water at all. Just want to be sure before I order the part.

    #143632

    Re: F&P GW709AU

    YES. The W/M does a self check diagnostic test, and it is picking up that there is no circut through the hot valve. It does this by pulsing voltage aroung the W/M, while it looks for certain signals 😉

    #143633
    admin
    Keymaster

    Re: F&P GW709AU

    I called and apparently that part no. doesn’t exist. They state that the hot water inlet valve is part no. 426142.

    Same thing???

    #143634

    Re: F&P GW709AU

    No, your WM is a phase 5, the part no they gave you is for phase 1 – 4. Tell them the Model No and they will give you the right one. 😉

    #143635
    admin
    Keymaster

    Re: F&P GW709AU

    Well I managed to get the right part, 420148.

    I’ve installed it and the same fault still exists. Just wasted $36.

    The machine doesn’t fill with water and the lights 00110010 are displayed after a couple of minutes and if I check in diag mode.

    HELP!

    #143636

    Re: F&P GW709AU

    Strangely I have come across the same problem with an 09 WM today, and the hot valve did not work, although it said in diagnostics the valve was faulty. I suspect the motor controller is faulty, but wont know for sure until Thursday. Controller PN 426974p. 😕

    #143637
    falcc
    Participant

    Re: F&P GW709AU

    In this thread http://www.ukwhitegoods.co.uk/modules.p … pic&t=6501
    alexa says that the cold valve is proportional and indicates that the hot valve isn’t. On the packaging for 420148 it states it is a proportional valve.

    Maybe it IS the wrong part??

    #143638

    Re: F&P GW709AU

    You are right. The hot valve part no is 420147, but it does not affect the operation, as the valve coils (electrical part) have exactly the same resistance. The proportional part is when the valve shuts off, the hot is on or off, the cold can be gradually closed by altering the voltage to the coil.

    #143639
    admin
    Keymaster

    Re: F&P GW709AU

    How did you go today? My washing is starting to pile up 🙂

    #143640

    Re: F&P GW709AU

    Yes, it worked. However I did replace the hot valve as it had a crack in it, but this didnt change the initial hot valve fault as I metioned earlier.

    #143641
    falcc
    Participant

    Re: F&P GW709AU

    So you replaced the motor controller?

    Is there anything else that could be causing the same error? The motor controller is expensive so I don’t want to buy the wrong thing and waste a lot of money.

    Thanks for your continual support.

    #143642
    FastAndPro
    Participant

    Re: F&P GW709AU

    Its a comman fault on phase 5 machines the solinoid goes on the cold water and damages the module. It then gives the error code for the Hot inlet. They can be repaired.

    #143643
    sclarke7171
    Participant

    Re: F&P GW709AU

    Hi Guys,
    just joined as my machine is not working, same exact fault.
    wish i had have stayed in the whitegoods industry today….. but computers pays more.
    Anyhow.
    Same fault, wont fill and when emptying the motor pumps and spins for a few secs and stops, then again for a few secs and then stops. the time it runs for is and intermittant time frame.
    Diags shows up as
    00110010

    and strangley after 3 mins off it running that fault comes up also.
    i’ll check the hot valve in the morning for resistance. so it should be about 60 ohms?

    Please help. Wife is not happy about the Laundry mat as her place to be nightly

Viewing 15 posts - 1 through 15 (of 29 total)
  • You must be logged in to reply to this topic.