Hoover AL 120

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #11345
    rocker
    Participant

    This machine appears dead, have mains power in Interlock engages. machine Dead..

    I fitted a new pcb timer,only to find same fault..

    This machine has a PCB timer fitted top of machine..
    have 240volt postive from on/off switch feeding into pcb..but when I tested the line in plug that enters into front of pcb..positive line only has 112 volts. Negitive ok. ( on checking the wiring this line comes via another part of the pcb. through the heater and back into front of pcb.

    have checked heater/water valves for open circuits all ok

    has anyone any ideas please..

    #144947
    Martin
    Participant

    Re: Hoover AL 120

    rocker,

    I have emailed you the relevant wiring diagram which may help you out of this one 😉

    #144948
    Phidom
    Participant

    Re: Hoover AL 120

    If you are talking about AC voltages, live & neutral might make more sense. 😉

    #144949
    andy2
    Participant

    Re: Hoover AL 120

    Rocker if this is a six that uses the motorised selector switch have a look at my thread here:-

    http://www.ukwhitegoods.co.uk/modules.p … pic&t=7478

    Andy

    #144950
    rocker
    Participant

    Re: Hoover AL 120

    thanks you all for your help..I went back to this machine today, and done some more investigation.. the drain pump was open circuit…should have tested in the 1st place ….learnt a lession..
    cheers (rocker)