AEG cooker B4100-1-d Fan Running Continuously

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries AEG cooker B4100-1-d Fan Running Continuously

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #11396
    bobokines
    Participant

    Prod code 944181737

    Hi

    Can someone please confirm the part number for the cooling fan thermostat on this oven. It’s the tiny stat taped to the harness with two white and two blue wires.

    I think it’s 8996619265482

    It’s nil stock and I don’t want to let my customer wait and then find it’s the wrong bit
    Many thanks

    Bob

    #145205
    Dave_Conway
    Participant

    Re: AEG cooker B4100-1-d Fan Running Continuously

    It’s part number 8996619267611 Bob.

    To confirm, have a look at the product in the shop:

    http://shop.ukwhitegoods.co.uk/89966192 … an-control

    That’s the one isn’t it ?

    Dave.

    #145206
    bobokines
    Participant

    Re: AEG cooker B4100-1-d Fan Running Continuously

    ER? the picture looks like four amp tags leading nowhere?

    Thanks for that, The part has been fitted before and the customer has a ServiceForce invoice with that part number on it.

    thanks again Dave

    Bob

    #145207
    eastlmark
    Moderator

    Re: AEG cooker B4100-1-d Fan Running Continuously

    Yep, that picture has to win the most useless part picture of the year!
    Actualy, we are fitting loads of these right now, usual complaint being the oven cutting out completely when hot as the cooling fan is not being initialised. ID of this part is not helped by it not being shown on TDS or Pro corner and it being offically described as a “thermal cut out” which it is not. It first appears to be just a join of 4 wires but is infact a tiny heater strip wired in series with the oven fan element, the current for which heats up a bi-metal strip that initialises the cooling fan motor after a while. The object being that even when the oven is turned off, the cooling fan will continue to run until the bi-metal cools down and breaks to circuit. Simpl? yes, cheap? yes, reliable? NO.

    #145208
    bobokines
    Participant

    Re: AEG cooker B4100-1-d Fan Running Continuously

    It obviously fooled the ServiceForce engineer on this machine as he fitted FIVE components on the previous invoice for the same fault ❗

    Thanks for the explanation.

    Bob

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.