Re: Blomberg 1515aaa flashing lights
Blomberg is a brand name used by Comet. In my experience, once the guarantee period has passed there is no chance of “free” support. Unfortunate really, as these are well made German built appliances by the Brandt company. Their technical support is notoriously poor amonmg the trade members of this site.
So – apply some logic. You both say that the machine runs for a while, before faulting. Possibilities – not reaching the required temperature in the time allowed (heater circuit failure); not draining out in the time allowed (blockage, drain restriction, pump failure); draining but thinking it’s still full (level system blockage/switch failure); possibly not even reaching the required water level in the time allowed (water valve failure).
At best, the “codes” are a guide, most faults can be solved by a methodical approach, observation and some careful testing (with the power off).
If you are unable to do this safely, please check repairs@ or Directories for a UKW engineer in your area.
Regards,
Penguin45.