Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › bosch dryer 3204gb
- This topic has 11 replies, 5 voices, and was last updated 20 years, 7 months ago by
electrofix.
-
AuthorPosts
-
September 12, 2005 at 12:37 pm #11927
electrofix
ModeratorBosch Tumble dryer 3204gb/09
dryer starts up in a clockwise direction and heater relay engages
dryer stops to reverse and starts going in anti clok direction but heater relay does not engage
when dryer stops again to go clockwise heater relay engages (somtimes)
have checked exhaust thermistor and am getting around 11k tried a 5k6 resistor in place of and got no difference
if i disconnect thermistor i get a flashing iron dry light another one for your fault codes list
anyone any ideas on this one even put wet clothes in it to see if it made difference but no
any ideas would be good
thanks Dave
September 12, 2005 at 2:49 pm #147203Simon46
ParticipantRe: bosch dryer 3204gb
Is this the one with the carbon brush which wears out on the drum?
September 12, 2005 at 2:53 pm #147204electrofix
ModeratorRe: bosch dryer 3204gb
yes it is the one with the carbon brush have held brush in contact and does not seem to change problem
there is a setting for a 30 min cycle since this is timed i would not expect the sensors to be active but i may be wrong
Dave
September 12, 2005 at 4:08 pm #147205Martin
ParticipantRe: bosch dryer 3204gb
Please give us the correct model number, it really would help 😉
September 12, 2005 at 5:52 pm #147206Simon46
ParticipantRe: bosch dryer 3204gb
Does it work o.k on 30 minute cycle?
S.
September 12, 2005 at 7:28 pm #147207Martin
ParticipantRe: bosch dryer 3204gb
…by the way, because the fan only blows air in one direction only and thru the element box, during the short 3 second reverse tumble its not blowing and so the element switches off to prevent overheating !
September 12, 2005 at 7:43 pm #147208superfix
ParticipantRe: bosch dryer 3204gb
Depending on model,m/c does not pull full current for at least 5 mins.As comparison is made between ntc’s.If you disconnect one then it will show fault.
Have you checked carbon pick up on rear bearing?
HTH
September 12, 2005 at 8:55 pm #147209electrofix
ModeratorRe: bosch dryer 3204gb
sorry had not noticed i had not put letters in model no will post tomorrow when i have checked cant remember them
@ simon46 no it does not work any better on 30 cycle
will take off element cover and check for a carbon pickup
there were one or two times when the element came back on for a second time but then failed later. its like the board is being told to keep element off through a faulty sensor or the like
thanks for all help so far
Dave
September 14, 2005 at 8:41 pm #147210electrofix
ModeratorRe: bosch dryer 3204gb
full model no WTA 3204 gb 09
sorry for omission
February 26, 2007 at 6:18 pm #147211clivejameson
ParticipantRe: bosch dryer 3204gb
Did you get a fix for this one electrofix? I’ve got the identical model (WTA3204/GB09 Fd 8306) with exactly the same problem namely it only powers the heater in the anticlock direction and the drum brush contacts appear healthy.
If anyone else has come across this i’d be pleased to know the outcome.
February 27, 2007 at 8:54 am #147212clivejameson
ParticipantRe: bosch dryer 3204gb
Anyone?
March 8, 2007 at 11:43 am #147213electrofix
ModeratorRe: bosch dryer 3204gb
never really got an answer to this one dryer seemed to right itself but has now been scrapped by customer as the heater failed still have dryer looking for s/h heater or will try to fix original if i get time
Dave
-
AuthorPosts
- You must be logged in to reply to this topic.