    Toni
    Participant

    Hi,
    I have a call today to the above machine
    The symptons are that the machine is dead, the lights come on & the interlock locks. I have had the module tested by QER who can find no fault with it.
    Has anyone had one of these faults ? any ideas ?
    Any help would be very much appreciated

    Regards
    Toni

    #154669
    Martin
    Participant

    Re: Hoover 1300SE

    I’ve never heard of a 1300SE is that the correct model number Toni ?

    #154670
    Toni
    Participant

    Re: Hoover 1300SE

    Thats what the customer gave me
    I will check it out when I call later this morning

    Toni

    #154671
    Toni
    Participant

    Re: Hoover 1300SE

    Sorry 😳
    Model PE235-001

    Toni

    #154672

    Re: Hoover 1300SE

    Seem to remember a lot of New Wave machines going dead when the pump got blocked or went o/c. (But could be just my poor memory?).Anyway presumably this is a Candy/Hoover?Presume water valve solenoids were checked.
    Mike.

    #154673
    Toni
    Participant

    Re: Hoover 1300SE

    Spot on Mike
    Pump open circuit

    Cheers
    Toni

    #154674

    Re: Hoover 1300SE

    Just shows you get one right occasionally if you keep firing. 😀
    Mike.