hoover TC650 dryer

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #15858
    abbots
    Participant

    hi guys,
    hvr condensor dryer TC650 001 37616323

    went to no heat problem.stat on top of element faulty,condensor blocked solid.
    no worries so far.
    replace element and clean condensor,sorted(i thought)
    put it through a short test run,electrical safety,function test etc.
    the dryer drum does not stop when the door is opened,the heater stays on when the timer has finished and the stop position for the timer is at 4 o clock instead of at the top i.e. 12 o clock.this is in a pub and get’s load of stick.
    do you thing the timer contacts are “fused” together and not switching as they should,or do you think someone has turned timer the wrong direction and damaged it.
    i’ve checked all the obvious,door microswitch,start relays etc.
    the only thing i can come up with is the timer,has anyone come across this before?
    cheers .
    john

    #166591
    timdowning
    Participant

    Re: hoover TC650 dryer

    just a thought, had a few where the timer knob slips on the shaft (when timer is turned the wrong way), it then makes you think the timer is out when actually it just the knob. There is also a start relay board which should de-energise when the door is opened, this fault may of been there before you visited.

    #166592
    abbots
    Participant

    Re: hoover TC650 dryer

    i thought it maybe the start relay board at first,had one on the van ,but it made no diffence,thats why i thought the contacts maybe shorted together in the timer.
    jk

Viewing 3 posts - 1 through 3 (of 3 total)
  • You must be logged in to reply to this topic.