Hotpoint WM62

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #15985
    SWERV
    Participant

    😕 I was wondering if any one has come across this? Went to the above machine and the timer had blown a couple of tracks as well as the 13amp fuse. done all usual earth checks and went through all components, everything checked ok.Fitted new timer assy and as soon as I switched it on bang!! blew the timer again. I disconnected the pump leads from the timer and metered it and it was a dead short across the terminals.of the pump.I thought I’d check everything again to be sure and then went back to the pump and this time it metered ok. 😕 I checked all wiring which all looked ok.
    Any Idea’s
    Merv

    #167103
    Penguin45
    Participant

    Re: Hotpoint WM62

    Interlock is the usual culprit for blown tracks- not had a pump do it on one of these.

    Chris.

    #167104
    whitevanman
    Participant

    Re: Hotpoint WM62

    maybe door lock blown because hole in door seal 🙄 or motor shorted on com or field ?

    wayne