  • #16698
    SDR
    Participant

    can anyone help, i have a diplomat built in ADP8112 d/w lights 1 and 5 come on after about 3 mins, machine fills a bit and empties but nothing else, i guess at wash motor, but have no codes for this machine.

    #171099
    Dave_Conway
    Participant

    Re: DIPLOMAT ADP8112 LIGHTS 1 &5

    In the known error codes under Smeg 😉

    SMEG error codes….

    Well it keeps coming up, so someones got to do it…….

    E1 – 1st flashing, 5th lit – flood protection system activated.
    E2 – 2nd flashing, 5th lit – safety pressure switch activated.
    E3 – 1st, 2nd flashing, 5th lit – no heat in time allowed.
    E4 – 3rd flashing, 5th lit – temperature sensor fault.
    E5 – 1st, 3rd flashing, 5th lit – no fill.
    E6 – 2nd, 3rd flashing, 5th lit – no drain in time allowed.
    E7 – 1st, 2nd, 3rd flashing – flow meter detected when not fitted Very Happy – reset required.
    E9 – same code as E1, so how you tell the difference is beyond me, but is a related fault to E1 + E2.

    Dave.

    #171100
    SDR
    Participant

    Re: DIPLOMAT ADP8112 LIGHTS 1 &5

    cheers dave, i will know where to look next time 8)

    #171101
    Dave_Conway
    Participant

    Re: DIPLOMAT ADP8112 LIGHTS 1 &5

    Sorry, the “Well it keeps coming up, so someones got to do it……. ” was copied straight over as I was in a rush 😉