WFT2800GB/12 Not Heating Water

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries WFT2800GB/12 Not Heating Water

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #17299
    Turbo
    Participant

    Element is ok. There is no live supply to the element though. Displays fault 4 with dryer light flashing. also the final rinse light is lit. Suspect main board. Would be gratful for any advice as the board are £174+.

    Many Thanks Turbo

    #173709
    Dave_Conway
    Participant

    Re: WFT2800GB/12 Not Heating Water

    Moved to the trade area turbo 🙂

    Dave.

    #173710
    gegsy
    Participant

    Re: WFT2800GB/12 Not Heating Water

    Sounds to me like the heater relay on main module (K3) poor contacts.
    The PCB is p/no 295666, or if you up for it you could locate relay and try and match it up 🙂

    Greg

    #173711
    Turbo
    Participant

    Re: WFT2800GB/12 Not Heating Water

    Thanks Greg
    Very helpful advice, waiting for customers to decide.
    Turbo.

Viewing 4 posts - 1 through 4 (of 4 total)