Help please.
Brandt model CFB200WU
Can anyone give any knowledge to this fault?
😕
Gutter in freezer blocked with ice, freezer and fridge section not cold enough, compressor only runs for a few minutes, fridge back panel has overall frosting.
No problem with compressor, I have checked the de-frost heaters for the freezer, fan ok, not sure of the resistance of the freezer thermistor. Measured approx 8k@ -9deg.
I suspect PCB but I do not have one to swap test, so need to confim that all is ok before ordering one.