Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Creda 17084E DC 56163086
- This topic has 16 replies, 5 voices, and was last updated 19 years, 8 months ago by
Alanj.
-
AuthorPosts
-
August 5, 2006 at 3:03 pm #19708
Alanj
ParticipantHi Guys,
has anyone out there got wiring diagrams for the above appliance?
A copy would be most helpful.Thanks
Alan
August 6, 2006 at 10:36 am #184198Alanj
ParticipantRe: Creda 17084E DC 56163086
If anyone has a wiring diagram, it’s the connection diagram for the pressure switch I am looking for.
Thanks
Alan
August 6, 2006 at 11:26 pm #184199iadom
ModeratorRe: Creda 17084E DC 56163086
I don’t have a Creda manual but as this is a Hotpoint clone, we could possibly narrow it down to a similar Hotpoint model if you can give me the wiring colours, pressure switch terminal numbers and the destination of the wires from the pressure switch.
Jim.
August 7, 2006 at 12:19 pm #184200Alanj
ParticipantRe: Creda 17084E DC 56163086
Hi iadom,
It,s a 2 level P/switch with 8 wires,as follows
Red – p/sw to hot valve
purple /grn – p/sw to heater
red/grn – p/sw to door/sw
blu – p/sw to 3way cold valve
black ps eleven – p/sw to timer edge con 8
white one – p/sw to timer edge con 5
white two – p/sw to timer edge con 7
white four – p/sw to timer edge con 6red/gn and white one are piggybacked on p/sw
p/sw connections 11,12,14, 31,32,34,36.
hope this is helpful.
AlanAugust 7, 2006 at 4:22 pm #184201iadom
ModeratorRe: Creda 17084E DC 56163086
Unfortunately none of the WM ones I have a remotely like that I’m afraid.
I went to a 17087 today and made a note of the P/SW wiring just in case bit it was nothing like that. 😥Also Partfinder lists pressure switch as a 3 level which I would expect with all those connections although the numbers you give don’t tie up with a 3 level switch. 😕
I have made an enquiry to a contact who is going to have a look through his collection. 😉August 7, 2006 at 4:43 pm #184202Dave_Conway
ParticipantRe: Creda 17084E DC 56163086
Here’s the Hotpoint model the pressure switch is fitted to if anyone has the info:
9529A, 9529P, 9529W, 9539A, 9539P, 9539W, 9549A, 9549P, 9549W, 9777P, WM23A, WM23P, WM23W, WM26A, WM26P, WM26W, WM31A, WM31P, WM31W, WM32A, WM32P, WM32W, WM35A, WM35P, WM35W
Part number 1600856.
It’s actually a 3 level (the 3rd being the silent touch contact for flood protection – this will be terminal 36).
The other two levels will be:
Level 1 – common = 11 – 12 and 14 will be n/o and n/c
Level 2 – common = 31 – 32 and 34 n/o and n/c etc.That may help a bit ?
Dave.
August 7, 2006 at 5:38 pm #184203iadom
ModeratorRe: Creda 17084E DC 56163086
Numbers don’t match the WM31/32/35 manuals Dave.
The numbers in the Hotpoint manual for those are the usual 11.12.14-21.22.24 & 31.32.34 No #36?
Also checked the manuals for 9529/9539/9549 & 9777 they are all the earlier timer with module clipped at the rear.or side of timer, not the hybrid timer.
Jim.
August 7, 2006 at 7:20 pm #184204iadom
ModeratorRe: Creda 17084E DC 56163086
Just thinking about this I have fitted the odd pressure switch to this range although not very often. I seem to remember that the replacement pressure switch was a later type that included a few wiring mods, perhaps this machine has the later switch fitted as standard.?
Unfortunately I don’t have the details of the modifications to hand. 😥
August 7, 2006 at 8:29 pm #184205Alanj
ParticipantRe: Creda 17084E DC 56163086
Hi Guys,
if this helps the timer is a 904 2425 02.
Alan
August 7, 2006 at 8:49 pm #184206Dave_Conway
ParticipantRe: Creda 17084E DC 56163086
iadom wrote:I seem to remember that the replacement pressure switch was a later type that included a few wiring mods, perhaps this machine has the later switch fitted as standard.
Yeah, sorry, the pressure switch is only fitted to later models with the hybrid timer unit.
Order a pressure switch, it may come with the diagram as part of the mod 😉
Dave.
August 7, 2006 at 9:27 pm #184207iadom
ModeratorRe: Creda 17084E DC 56163086
Alanj wrote:Hi Guys,
if this helps the timer is a 904 2425 02.
Alan
Not really Alan, that timer or its replacements fit well over 30 different models.
August 8, 2006 at 9:51 pm #184208Dave_Conway
ParticipantRe: Creda 17084E DC 56163086
Alanj wrote:Hi Guys,
does anyone have a copy of the wiring diagram that is packaged with the above pressure switch, or a copy of a Creda 17084E manual.
Alan
Copied here to keep things tidy 😉
August 9, 2006 at 7:12 pm #184209HotDog
ParticipantRe: Creda 17084E DC 56163086
Copy of manual on its way to iadom 😉
August 9, 2006 at 7:41 pm #184210iadom
ModeratorRe: Creda 17084E DC 56163086
Fantastic Cliff, if you make it to the September meeting I owe you a pint. 😆
Jim.
August 20, 2006 at 10:19 am #184211Alanj
ParticipantRe: Creda 17084E DC 56163086
Is there no ex Hotpoint engineer with this info out there?
Alan
-
AuthorPosts
- You must be logged in to reply to this topic.