Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › WHIRLPOOL S20ER Side by side F/F
- This topic has 13 replies, 4 voices, and was last updated 19 years, 7 months ago by
machineman.
-
AuthorPosts
-
September 4, 2006 at 6:36 pm #20566
machineman
ParticipantNO temp read out on panel just a warning triangle and the middle line on each of the digits light up, any thoughts would be welcome.M
September 4, 2006 at 8:06 pm #187509admin
KeymasterRe: WHIRLPOOL S20ER Side by side F/F
Try switching off for 5 seconds and switch back on. As this is the “timer” with the rear PCB being the “controller” I’d go for faulty timer, ie new display required.
hope that helps
Kevin
September 4, 2006 at 8:20 pm #187510machineman
ParticipantDo you mean switch the mains off for 5 secs,and whats with the triangle.m
September 4, 2006 at 9:27 pm #187511admin
KeymasterRe: WHIRLPOOL S20ER Side by side F/F
Yes the mains, the triangle I’ve never seen, I’d have to think it’s not a rear pcb generated fault therefore it’s the display at fault.
Kevin
September 5, 2006 at 8:43 pm #187512machineman
Participantcalled today switched off then back on dispay ok set for -18 and 5 cust said she had to keep f/f switch on to keep freezing .the little triangle is a warning light when temp to high. works for about 20 mins alarm goes off little triangle lights up .only centre digits off freezer temp alight fridge digits ok at 5.any ideas welcome and would you still go for display board .M
September 5, 2006 at 9:30 pm #187513DentedPorsche
ParticipantRe: WHIRLPOOL S20ER Side by side F/F
No, it’s an error code being displayed. Double dashes in the freezer display indicate the temperature has risen above -13.
Check that the compressor fan is running, compressor not overheating and cutting out. Main PCB may be the culprit. Don’t have the manual to hand just now but if no one else comes along with the answer I’ll dig it out tomorrow after work.Brian
September 6, 2006 at 7:24 am #187514machineman
ParticipantNot the comp it runs normally on fast freeze,M
September 6, 2006 at 7:51 pm #187515DentedPorsche
ParticipantRe: WHIRLPOOL S20ER Side by side F/F
OK, got the training manual open and it says, verify that the compressor, the evaporator and compressor fan are working and measure the internal temperature. Replace the main board.
Basically, if all checks out ok the board is at fault. No mention of the freezer probe (NTC) though. Freezer probe is the 4 way connector on the board and uses pins 1 and 3.
Brian
September 24, 2006 at 7:38 pm #187516machineman
Participantok changed the main board , still icing up and not defrosting checked heater not o/c .m
September 24, 2006 at 9:35 pm #187517DentedPorsche
Participantmachineman wrote:still icing up and not defrosting
Emmm, this is the first mention of icing up and not defrosting.
I’ll bring the manual home again tomorrow, if no ones answered I’ll see whats in there.
Brian
September 24, 2006 at 10:00 pm #187518EFS
ParticipantRe: WHIRLPOOL S20ER Side by side F/F
If it won’t do a defrost it is probably the defrost stat on the evaporator.
You will find it listed as “Cable harness bi-metal” 481232058132.
About £21 trade.Steve
September 26, 2006 at 8:57 pm #187519machineman
Participantwhats in that little black box .m
September 27, 2006 at 5:57 pm #187520EFS
ParticipantRe: WHIRLPOOL S20ER Side by side F/F
The wiring diagram shows a thermal fuse & a thermostat.
No values are listed.Steve
September 27, 2006 at 8:18 pm #187521machineman
Participantcheers thanks for the replies.m
-
AuthorPosts
- You must be logged in to reply to this topic.