whirlpool large American tumble dryer 10 kg 110 volts

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries whirlpool large American tumble dryer 10 kg 110 volts

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #20934
    The-specialist
    Participant

    hi

    hope someone can help with this dryer,the fault is that
    when you press the start button it turns the drum for a few seconds and then blows a small inline fuse in the wiring loom.
    have traced the wire from the fuse one goes down to a front stat in base
    the other goes to the control panel where it splits into 3 wires
    1/to the timer 1/to the start button 1/to the buzzer
    I have checked the heater /motor and stats all seem ok and have no leak to earth on insulation
    any ideas would be of help . and thanks for looking .
    thanks 🙂 :rolls:

    #188853
    Penguin45
    Participant

    Re: whirlpool large American tumble dryer 10 kg 110 volts

    You sure about the run winding on the motor? Most of these have a centrifugal start device, which can take a second or two before it throws the run winding on,

    Chris.

    #188854
    The-specialist
    Participant

    Re: whirlpool large American tumble dryer 10 kg 110 volts

    I think it has got a centrifugal start device on the motor will check it out but have already had megger on windings and they seemed to be fine .
    thanks for your info 🙂

    #188855
    gegsy
    Participant

    Re: whirlpool large American tumble dryer 10 kg 110 volts

    Hi
    Change the 6.3 amp inline fuse for a 10 amp, that should sort it 😉

    Greg

Viewing 4 posts - 1 through 4 (of 4 total)