Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › amana SRD522S
- This topic has 7 replies, 5 voices, and was last updated 19 years, 6 months ago by
PINKY.
-
AuthorPosts
-
September 22, 2006 at 12:24 pm #21061
PINKY
Participantafternoon chaps, i have a fault on this. when i went on weds the fan in the freezer was not running and the evap was frozen up. fan tests ok and once i had defrosted the evap the fan started running again. went back today and the fan is no longer running and the evap is froxen up again as a result of this.
Does any one know what brings the fan on, i assume it should start up as per the stat or H4 device?
cheersSeptember 23, 2006 at 3:40 pm #189343cab
ParticipantRe: amana SRD522S
Hi not heard of this make before, but most fans run while the compressor runs. If the evporator is frozen it isnt defrosting!
It might have a mechanical defrost timer on the back which might be sticking, defrost element/stats open circuit. or if its electronic control it might be that.cliff
September 24, 2006 at 8:12 am #189344burns
ParticipantRe: amana SRD522S
cab,
Have you much experience of the Amana, I am looking for a service agent to cover Sheffield / Chesterfield area any interest.
If so please email your details and anything describing your background.Thanks
Steve Burns
Maytag UKSeptember 24, 2006 at 7:10 pm #189345lokring
ParticipantRe: amana SRD522S
mmmm!!
sounds interesting…….. 😀 😀September 24, 2006 at 9:16 pm #189346burns
ParticipantRe: amana SRD522S
We have a local engineer who cant keep up with the work, any ideas :rolls:
September 25, 2006 at 12:32 pm #189347PINKY
ParticipantRe: amana SRD522S
cab, you’ve never heard of Amana before? I was after someone with some knowledge of these products.
September 25, 2006 at 1:20 pm #189348cab
ParticipantRe: amana SRD522S
hi a fridge is a fridge! 😕 If the evaporator is frozen it isnt defrosting!
cliff
September 25, 2006 at 2:23 pm #189349admin
KeymasterRe: amana SRD522S
hi
the fan is operated by a defrost klixon with orange and grey wires if i remember right and also there is also a thermal overload with 2 blue wires that operat the defrost heater section,by defrosting the evaperator then you are basicly by passing the fault,the unit has a mechanical defrost timer normally at the bottom left or centre of the appliance behind the plinght or in the fridge section top right,
you can turn this manually to force a defrost and test the nessasery parts.bryan
-
AuthorPosts