white knight t/d cl767sv

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #21541
    williemac
    Participant

    dryer runs for 20 mins then goes cold,checked filter,condenser and water container, and there are no leaks.reset stat and it will go again no blockages

    #191285
    whitevanman
    Participant

    Re: white knight t/d cl767sv

    am sure this model has got a sensor on drum ???

    #191286
    maltheviking
    Participant

    Re: white knight t/d cl767sv

    whitevanman wrote:am sure this model has got a sensor on drum ???

    If it has try it with damp washing 😉

    #191287
    DentedPorsche
    Participant

    Re: white knight t/d cl767sv

    williemac wrote:reset stat and it will go again no blockages

    Just to make sure I’m reading this right. Do you mean it runs and trips the stat after 20 mins?

    If so and assuming air flow across the heater is ok I can only think it may be a faulty stat?

    Brian

    #191288
    cab
    Participant

    Re: white knight t/d cl767sv

    hi cl767sv standard crosslee condensor drier suffix sv for silver? If motor and fans are ok filters etc, the stat under drum is usually at fault. Bit of a pain to do, back off, drum out.

    cab

    #191289
    agro
    Participant

    Yep and dont forgetto tale a spare fan because if its seized then dont pull it you will damage the motor arm and boy do they get noisy.If fan at back stuck crack with screwdriver the cost of a fan is cheaper then a new motor

    #191290
    williemac
    Participant

    Re: white knight t/d cl767sv

    thanks everyone it was the stat

Viewing 7 posts - 1 through 7 (of 7 total)