Hotpoint wdm73 E16

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #22198
    onecallpaul
    Participant

    Getting e16 code which indicates overfill but the level looks fine.Pressure vessel and hose were clear .The switch clicked on and off ok[single level] is it likely to be the p/switch or a board fault.

    #194002
    DAZ123
    Participant

    Re: Hotpoint wdm73 E16

    i’ve had an earth fault on the heater show up strange faults on these models before, so might be worth checking. have you tried setting program and blowing into the p/switch to see if it sets?

    #194003
    onecallpaul
    Participant

    Re: Hotpoint wdm73 E16

    Cheers will go back and check heater had to get out quick because the parking restrictions only gave 20mins…nightmare