Indesit WD12 uk

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #24742
    gs550rider
    Participant

    Hi there. Can any body shed some light on my problem with my indesit wd12. It started with the error LED flashing 10 times and doing the rotating knob thingy whilst trying to pump out non existant water. Now however this has stopped. I still get the 10 error flashes but now the dryer heater starts up whilst doing the rotating knob thingy lol. Well I aint got a clue so any input would be most apreciated.
    Many thanks
    Dave

    #203157
    Penguin45
    Participant

    Re: Indesit WD12 uk

    Problem with the water level control system. Air collection bell may be choked, air hose blocked, trapped, pinched or even holed. The pressure switch may be faulty. Wiring between switch and control board may be faulty. Control board itself may be faulty.

    So, just a few possibilities 😀 . If you’re not sure how to proceed, time for pro help – click the link below.

    Power off if you are going to investigate.

    Regards,
    Penguin45.