hotpoint ffa60

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #25485
    waters
    Participant

    Just got in to check.Fridge temp ok but freezer runs at -10.Any advice please

    #206023
    indespoint
    Participant

    Re: hotpoint ffa60

    Hi check duct in freezer is not blocked with ice. If thats ok change PCB. Thermistor in freezer is not replacable

    #206024
    waters
    Participant

    Re: hotpoint ffa60

    Thanks,only been running a day so looks like pcb then.

    #206025
    subs
    Participant

    Re: hotpoint ffa60

    indespoint wrote:Hi check duct in freezer is not blocked with ice. If thats ok change PCB. Thermistor in freezer is not replacable

    😕 Hi indespoint i have a question. When you say the thermistor is not replaceble is it because it is moulded in and what if it IS faulty, changing the board won’t cure the fault will it? I’m only curious to learn because i’ve come accross faults with F/freezers with moulded in ntc’s (proline and ocean) and changed the board with no joy and basicly its a throw away job.

Viewing 4 posts - 1 through 4 (of 4 total)
  • You must be logged in to reply to this topic.