    Hi,
    First customer calls, LED 3 on, not flashing, nothing happening.
    I do reset proceedure and get LED 1 flashing, shut door and pump works and doesn’t stop.
    I do reset again and LED 4+5 flashing, shut door and just pump again. No leaks in the tray so any ideas welcome. Not a fault listed for this.
    Thanks.
    Rob

    #221296
    clivejameson
    Participant

    Re: Smeg DW1612C…ser. 00504502

    Hi Rob

    With spurious fault indications like this you can only check the obvious like earth faults, wiring harness etc….if it’s none of those then the pcb is a gonner 😕

    #221297
    Oldtog
    Participant

    Rob,

    PCB replacement, sorry.

    #221298
    robbra
    Participant

    Re: Smeg DW1612C…ser. 00504502

    Thanks Clive and OT,
    Gonna give it one more look then break the news to her.
    Rob

    #221299
    Lawrence
    Participant

    Re: Smeg DW1612C…ser. 00504502

    Hang another solenoid on the Dispenser just to eliminate it ,sometimes causes spurious fault codes
    Lawrence

    #221300
    Oldtog
    Participant

    Re: Smeg DW1612C…ser. 00504502

    Lawrence this is true 😀 , however this normally causes the machine to give a spurt of life then stops, and continues like this until switched off 😕 . I have not found this coil to give a display fault though. However I have been wrong in the past and no doubt I’ll be wrong again 😳 .


    Oldtog

    #221301
    clivejameson
    Participant

    Re: Smeg DW1612C…ser. 00504502

    Oldtog wrote: I have not found this coil to give a display fault though. However I have been wrong in the past and no doubt I’ll be wrong again 😳 .
    Oldtog

    I have! sorry OT 😆