Bosch d/w SGS5318GB/12 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Bosch d/w SGS5318GB/12 This topic has 3 replies, 3 voices, and was last updated 18 years, 8 months ago by senseib. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts July 26, 2007 at 4:31 pm #29299 senseibParticipant Even when I reset the control module the circulating motor is running all the time on this machine & it wont drain unless i actuate the overfill switch. Can anyone advise? Brian. July 26, 2007 at 4:35 pm #222661 RedflameParticipant Re: Bosch d/w SGS5318GB/12 Sounds to me like you have a live feed to the motor – Could be module fault or could be element down causing neutral fault. Anyone else ? Martin ? July 26, 2007 at 5:25 pm #222662 senseibParticipant Re: Bosch d/w SGS5318GB/12 Thanks for your prompt reply Redflame. I tested both the heater element & the motor for earthing faults both ok. I suspect that it’s the control module, but always reassuring when others point the finger in the same direction. Does anyone know differently though? Brian. July 26, 2007 at 6:39 pm #222663 gegsyParticipant Re: Bosch d/w SGS5318GB/12 Hi Have sent some info that may help you. Greg Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In