Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Neff S5443 poor water circulation
- This topic has 7 replies, 6 voices, and was last updated 18 years, 7 months ago by
Seamy.
-
AuthorPosts
-
September 5, 2007 at 10:47 am #30305
Seamy
ParticipantHave to look at one of these 5years old (Integrated Neff S5443x2 GB17) dishwashers. Customer reports hardly any noise out of it & if they open door theres hardly any spray from spray arms at all, it does fill ok, filter in sump is clean. Do motors or capacitors give problems? I’ve looked at Connect & they list a circulation motor only ( not pump section) for £88.
September 5, 2007 at 3:13 pm #226712stu123
ParticipantRe: Neff S5443 poor water circulation
on some models there is a half load valve but generaly poor wash results are the complaint
September 5, 2007 at 3:13 pm #226713Martin
ParticipantRe: Neff S5443 poor water circulation
Seamy wrote:Do motors or capacitors give problems?
They either work or they don’t, usually the pump leaks into the shaft bearing and the whole lot seizes up. Prior to that happening the machine gets very noisy of course. 😉 Capacitors give no trouble in my experience.
Pump impellors never fail as a rule except when something like a teaspoon finds its way into the entry pipe, or pheasant was on the menu the night before and lead shot has buggered it up :rolls:
Seamy wrote:Customer reports
Yeah right… :rolls: Ask them the time of day and they never get it wrong but ask them what’s wrong with their machine ….??????? 🙁
September 5, 2007 at 7:12 pm #226714superfix
ParticipantRe: Neff S5443 poor water circulation
Check the sump hose and pressure chamber.
September 5, 2007 at 7:24 pm #226715gegsy
ParticipantRe: Neff S5443 poor water circulation
…….and also faulty water point unit on heater and/or module. 😀
You have mail seamy 😉Greg
September 5, 2007 at 8:22 pm #226716Seamy
ParticipantRe: Neff S5443 poor water circulation
Greg, many thanks for e-mail,
September 5, 2007 at 9:54 pm #226717gegsy
ParticipantRe: Neff S5443 poor water circulation
Most welcome 😉
Greg
September 5, 2007 at 11:11 pm #226718clivejameson
ParticipantRe: Neff S5443 poor water circulation
Sounds more like the impellor has sheared 😕
If you’re very lucky the shaft won’t be too rusted so you won’t need a new pump….just the impellor kit, but i’ve done a handful now and only one didn’t need a new pump despite attacking them with a wire brush 😯
Impellor kit is 183638
-
AuthorPosts
- You must be logged in to reply to this topic.