  • #30493
    rocker
    Participant

    Built in dishwasher.
    Have no negitive to heater..traced cable back to pressure switch..
    pressure s/w activates when I tested…I have continuity between pressure s/w to top facia on/off switch. cant test for power as I cant get meter probs into connections. am I missing anything and can anyone offer any advice, the next thing is to change the pcb…risky!!
    Cheers John.

    #227378
    senseib
    Participant

    Re: electrolux ESL6225 D/W

    Is the heater element chamber ok? – They go open circuit, common fault! (Part number: 50280071007)

    Brian.

    #227379
    rocker
    Participant

    Re: electrolux ESL6225 D/W

    Brian,
    Tested heater circuit ok..have no neg to heater !!

    #227380
    senseib
    Participant

    Re: electrolux ESL6225 D/W

    Most likely suspect PCB then… 😈

    Brian.

    #227381
    Penguin45
    Participant

    Re: electrolux ESL6225 D/W

    The “dry-joint-on-pcb” debate will start shortly………..

    Chris.

    #227382
    rocker
    Participant

    Re: electrolux ESL6225 D/W

    Chris, visual check on pcb, no sign of dry joints ??

    #227383
    Penguin45
    Participant

    Re: electrolux ESL6225 D/W

    Bumf in your in-box, Rocker.

    Chris.

    #227384
    rocker
    Participant

    Re: electrolux ESL6225 D/W

    Chris, cheers mate received info.
    John

    #227385
    admin
    Keymaster

    Re: electrolux ESL6225 D/W

    Sometimes I use one trick: measure where on interesting point (like pressure switch or heater) is coming L (live). After that I switch plug into main plug and see if I have L (live) came on other….if not I go thru this channel to see where is disconnected (interrupted). 😉

    #227386
    rocker
    Participant

    Re: electrolux ESL6225 D/W

    baron wrote:Sometimes I use one trick: measure where on interesting point (like pressure switch or heater) is coming L (live). After that I switch plug into main plug and see if I have L (live) came on other….if not I go thru this channel to see where is disconnected (interrupted). 😉

    ok, thanks for the advice – I’ve done these tests.

    John.

    #227387
    admin
    Keymaster

    Then you have found which wires from heater are comming to power PCB ( with water inside verify that electronics see heater). If it is OK look on PCB which relay is corresponding to heater and you will find him damaged or his tracks.

    #227388
    rocker
    Participant

    Re: electrolux ESL6225 D/W

    Baron, thanks for that will check this out.
    John

    #227389
    Alanj
    Participant

    Re: electrolux ESL6225 D/W

    Hi Rocker,

    are you getting L + N coming into machine? Have had instance where plug or socket were faulty.Try different socket?

    Alanj