Zanussi ZWX1605w

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #31109
    effzedarr
    Participant

    Bugging me is this one,select any prog & all the correct lights for that prog light up as normal,press start/pause button & nowt all lites go out door int’lock clicks, try again & again & eventually it starts up & away you go,pause the prog & you are back to square one,try ,try again & off you go. Checked lead from control board to PCB & cleaned connections,no joy,tried door i/lock as last resort & just the same ,PCB? If so is it a config job or plug in & away you go? Prod # 914517270/00
    Regards Chris…

    #229705
    cab
    Participant

    Re: Zanussi ZWX1605w

    97391451 72 70-00 / 0 comes configured. can you get into diagnostic to check fault code?

    cab

    #229706
    effzedarr
    Participant

    Re: Zanussi ZWX1605w

    I could if I knew how,not had much to do with these beasts,any clue how to access the diagnostics? Regards Chris…

    #229707
    Penguin45
    Participant

    Re: Zanussi ZWX1605w

    Stuff in your in-box, Chris.

    Chris.

Viewing 4 posts - 1 through 4 (of 4 total)