    Hello
    My Indesit WiDL126s is not draining
    I have fitted a new pump and checked all the pipes are clear but it still will not drain.
    The only thing I can think of is the powers not getting to the pump could anyone help ?

    Regards Brian

    #231765
    helo_75
    Participant

    unusual, and to be honest youd normally get a fault code if the pcb fails to energise the pump!!!

    do you hear anything when you turn it to spin/drain?

    #231766
    bis5
    Participant

    Re: Indesit WiDL126s is not draining

    Hi
    no I`ve tested it with the pump out to see if it is working but it`s not I put a electric screwdriver to the + and it`s only lighting the bulb very dim as though the powers weak ?

    #231767
    helo_75
    Participant

    ooh, live testing, shouldnt really be doing it

    could be the pcb, but youll need an eprom too

    but… could also be pressure switch, so its your call, id think the pcb would be most likely

    #231768
    bis5
    Participant

    Re: Indesit WiDL126s is not draining

    Hi
    how do I find the pressure switch as that may be the easy one to check.
    Thanks

    #231769
    bis5
    Participant

    Re: Indesit WiDL126s is not draining

    Hi
    Check the pcb and looks ok all joints look good no burn marks etc .
    Could you please point me in the problem fixing the pressure switch
    ie what part of the machine is it whats it look like.
    Thanks for any help