Re: Caple DI414 – will not complete cycle
F4 is a draining failure…so either it hasn’t drained, or it thinks it hasn’t drained.
First port of call is to check the pump…select any program and start, then hold the start button for about 5 secs to cancel the program, the pump should kick in for 1 minute.
If it hasn’t cleared the water then try the end of the drain hose if it connects to the sink waste fitting. After that it’s a strip-down job.
If it has successfully drained then next step is to check the water level detector…small black grid at about the 3 o’clock position in the sump under the filter. This can be cleaned with toothbrush/pipecleaner/hot water etc but note that there is a rubber membrane behind the grid which could be pierced by something sharp. If it’s particularly gunged it may need removing (access underneath).
Power off at all times :zap: