    Caple washer drier. Model no. WD1212. Nr. 01160 0205.

    Set a program. Runs for a couple of minutes then bleeps and shows F14 on the display. 😕 On tumble dry, there is no supply to the drier heater but the fan runs fine.
    I have tried the motor brushes and checked for loose and broken wiring. This machine seems to resemble a Hotpoint BDW12 with the PCB clipped behind the front panel above the filter. It also has a Bosch / Brandt type drier fan assembly in it.
    What does F14 mean – and any ideas how to cure it?

    Thanks,

    Steve.

    #233558
    Penguin45
    Participant

    Re: Caple WD1212 washer drier.

    Dryer NTC short/out of circuit.

    Chris.

    #233559
    aqualectric
    Participant

    Re: Caple WD1212 washer drier.

    Cheers, Chris!!
    Don’t suppose you have a part number for that NTC? 😉

    Steve.

    #233560
    Lawrence
    Participant

    Re: Caple WD1212 washer drier.

    Its a Smeg Steve if that helps.
    Lawrence

    #233561
    Penguin45
    Participant

    Re: Caple WD1212 washer drier.

    817870012

    Chris.

    #233562
    aqualectric
    Participant

    Re: Caple WD1212 washer drier.

    Thanks, guys!!! 😀