INDESIT IDL 500 NO HEAT

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #32286
    bib
    Participant

    ANY IDEAS FROM MEMORY I THINK THESE HAVE A SMALL CUT OUT WHICH SCREWS IN THE BASE

    #234459
    Penguin45
    Participant

    Re: INDESIT IDL 500 NO HEAT

    Screw-on safety – C00041086.

    Heater failure common on these, and the pcb is no great shakes either; thermistors pack in.

    Chris.

    #234460
    bib
    Participant

    Re: INDESIT IDL 500 NO HEAT

    THANK U QUEER THING IS IT GOES THROUGH THE PROG BUT WITH NO HEAT, CHECKED HEATER

    #234461
    Penguin45
    Participant

    Re: INDESIT IDL 500 NO HEAT

    I’d be suspecting that there PCB then.

    Chris.

    #234462
    admin
    Keymaster

    Check pressure switch… and NTC…
    From my data it’s BIT100 electronic… is it?.. you should receive error for that…
    If so, clean heater/fan relay or change him… and there is test program…

Viewing 5 posts - 1 through 5 (of 5 total)