SPS2462gb/18
Not filling, Inlet valve buzzing
The valve seems to have anti flood device, Can it be reset.
If i have to change valve, Is their an easy way to get at it.
pmb wrote:The valve seems to have anti flood device, Can it be reset..
Disconnect the inlet hose coupling first, then reconnect it to vent the inlet valve. Inside the base there’s a clear plastic tube with a stopper attached to the end near the drain pump, remove the stopper and drain off any water in the hose. That is the water block system. The inlet/safety valve is accessible only via lowering the base unit IIRC? 🙁
General if the valve has a anti-flood built into it you can remove valve and give it a shake over the sink which will remove the water that gets stuck in anti flood bellows part and will generally start working again. If happens again replace then. Hope this helps