WD12XUK F13 Fault

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #33545
    iadom
    Moderator

    Went out to this today. F13 Dryer NTC or jammed fan motor, fault intermittant.

    NTC appears to be OK. Fan motor with metal fan is fine.
    Is it still likely to be an NTC fault or possible poor module contacts?

    Jim.

    #239121
    helo_75
    Participant

    well

    nearly everyone ive done has been the ntc if im honest

    does it flash f13 even if you put it on wash?

    #239122
    Penguin45
    Participant

    Re: WD12XUK F13 Fault

    Had a few with the wiring broken inside the insulation at the NTC.

    Chris.

    #239123
    iadom
    Moderator

    Re: WD12XUK F13 Fault

    I had it running for 20 minutes, tugged the wiring to NTC ( this one has AMP tags) but it worked perfectly.

    I may try a new NTC, they are cheap so I will at least be proactive.

    Jim.

    #239124
    Simon46
    Participant

    Re: WD12XUK F13 Fault

    I took one out put it back it worked, so intermittent they can be.

    S.

    #239125
    iadom
    Moderator

    Re: WD12XUK F13 Fault

    Thanks for that Simon, or should that be Yoda. 😆

    #239126
    Simon46
    Participant

    Re: WD12XUK F13 Fault

    Hehe

    S.