Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › AEG condenser dodgy countdown
- This topic has 2 replies, 2 voices, and was last updated 18 years, 2 months ago by
simtoms.
-
AuthorPosts
-
February 5, 2008 at 8:40 pm #34365
simtoms
ParticipantLooking at an AEG condenser today which occasionally reverts back to 51 mins and start light flashes when it reaches 35 mins on display. Of course, unlikely to do it with engineer present… anyone help on activating a test mode for these? Thanks, Simon.
Mod is 57700W. PNC. 916014098. Ser. 12668558February 7, 2008 at 2:08 pm #242308trickydickyd
ParticipantRe: AEG condenser dodgy countdown
To begin the test programme push and hold the buttons ’door’ and ‘start / pause’ simultaneously.
At the same time turn the selector switch from ‘off ‘ to ‘light’. The timer display
will how show ‘do’.
To begin each separate function test, push ‘start / pause’.
Code Selector Switch Position Diagnostic Functiondo Light
d1 Cottons, Extra Dry Both heater relays are energised giving maximum
heating. Drum rotates left
d2 Cottons
Cupboard Dry
Heater relay c2.1 is energised giving 1400 watts.
Drum rotates left
d3 Cottons, damp Heater relay c2.2 is energised giving 1100 watts.
Drum rotates left.
d4 Cottons, Hand Iron Drum rotates left.
d5 Cottons, Machine Iron Drum rotates right.
d6 Easy Care Extra Dry Both heater relays are energised giving maximum
heating. Drum rotates left. With the drum empty,
machine switches off after 30 seconds and ‘END’
LED is illuminated. If short circuit exists between
drum and rib (paddle) machine will run
continuously.
d7 Easy Care To delete customer option setting push ‘Signal
button’. Machine returned to factory setting.
da 40 minutes All LEDs are illuminated. Pushing the signal button
will switch the buzzer On or Off.
Db 20 minutes Make good electrical connection between drum and
paddle. Push start/pause, S7 shows on display. Push
delay time to begin test. Display counts down to S0
(approx 30 seconds intervals). When test stops, if
end is illuminated the electronic sensing is correct.
If S1 or S2 shows on display, the electronic sensing
is faulty.Sorry if that looks a bit messy, copied and pasted from the diagnostic manual
February 8, 2008 at 8:00 pm #242309simtoms
ParticipantRe: AEG condenser dodgy countdown
😀 Thanks very much for that, sorry to be slow acknowledging. Will run test through and see what happens, Simon.
-
AuthorPosts
- You must be logged in to reply to this topic.