Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Compressor Alternative
- This topic has 9 replies, 5 voices, and was last updated 18 years, 1 month ago by
subs.
-
AuthorPosts
-
March 3, 2008 at 6:05 pm #35011
subs
ParticipantI need a compressor for this Lux made fridge freezer which the cust has imported from France. Mod ARF5299X. The compressor is a Lux made one, GVT75AA (R134A). Although i have not checked with the Lux group yet, i know the original will be expensive so am looking for a cheaper alternative.
Thanks
Subs
March 3, 2008 at 8:23 pm #244780Dales-Electronic
ModeratorRe: Compressor Alternative
Looks like its a fifth of a HP so you could use anthing with that size Aspera NB1116 etc, but to be sure I could do with the internal capacity in litres.
March 4, 2008 at 10:50 pm #244781subs
ParticipantRe: Compressor Alternative
Dales-Electronic wrote:Looks like its a fifth of a HP so you could use anthing with that size Aspera NB1116 etc, but to be sure I could do with the internal capacity in litres.
I was thinking myself about a 1/5 HP. Ill try and get the capacity. Spoke to Lux, apparently its Australian made, and they want £200 for compressor 😆
Thanks
Subs
March 5, 2008 at 7:13 am #244782admin
KeymasterRe: Compressor Alternative
Hi
Total volume is 470 litres.I havent got the cross over chart in my back pocket at the moment but the easy way to do it is as follows.
under counter fridge / bottle cooler 1/8 R600a
under counter freezer / square chest freezer 1/6 r600a
upto 5′ fridge freezer or fridge 4′ chest freezers 1/5 R600a
american or larger units 1/4 R600aBryan
March 5, 2008 at 7:54 am #244783Dales-Electronic
ModeratorRe: Compressor Alternative
If Bryans capacity is right you will need to us a quarter of a hp bearing in mind it is a two door.
On another point Bryan, whilst I appreciate that you retrofit R600a compressors (as I do too) to R134a systems (at our risk) it is not good practice to suggest this to others. In the case of Subs he could find himself in hot water if this repair goes wrong and the customer claims against him for both repair charges and loss of food. Or Milord he fitted an unapproved compressor to our Lux ff – guilty, £1K fine. 😡March 5, 2008 at 8:11 am #244784admin
KeymasterRe: Compressor Alternative
Hi Dales
The list doesnt mention retro fitting..lol. No advise given concerning cross overs,Just what calculations I use to choose the compressor size..
Would I do that…nooo.
Bryan
March 5, 2008 at 11:57 am #244785expertcat
Participant1/4hp r134a whirlpool part 481281729554
March 6, 2008 at 1:05 pm #244786subs
ParticipantRe: Compressor Alternative
Thank you all for your input. Thanks also for your concern but ive replaced quite a few compressors now and done a few retrofits. I also explain to cust that opening system can sometimes create problems such as blockages which are difficult to remedy, so there is an element of risk involved. I told this cust that i would try and get him another brand of compressor as Lux one would be expensive and it only lasted 4 years anyway. He was morer than happy.
Thanks
Subs
March 7, 2008 at 8:23 pm #244787spanner51
ParticipantRe: Compressor Alternative
Does any one use the Lokring system when fitting compressors?. Is it easy to use? Is it cost effective? I have been told not to braze connections on R134a systems, as it is potentcialy explosive.
March 7, 2008 at 8:48 pm #244788admin
KeymasterRe: Compressor Alternative
Hi
Brazing R134a explosive !! absolute cods wallop…He doesnt know what he’s talking about…
Brazing R134a is NOT explosive and is safe to do .
Bryan
-
AuthorPosts
- You must be logged in to reply to this topic.