Hotpoint RLA34P

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #35883
    Geoff1312
    Participant

    Hi Guys,
    Help! Called to a Hotpoint RLA34P freezing milk. Replaced stat (genuine Hotpoint 2603481)

    Customer has rung still not turning off. Any ideas please? ( Faulty new part?)

    Any ideas appreciated.
    Geoff

    #248516
    hotpnt
    Participant

    Re: Hotpoint RLA34P

    is the door sealing ok?

    #248517
    boselecta
    Participant

    Re: Hotpoint RLA34P

    does door fit properly?, does light go off when door closed?. Is it an exposed evaporator, if so can you reposition the capilary end to a different position on the evap plate?

    #248518
    admin
    Keymaster

    Re: Hotpoint RLA34P

    Hi

    If the stat is secured in the correct place where it freezes then the stat is either faulty or incorrectly wired.

    Bryan

    #248519
    Geoff1312
    Participant

    Re: Hotpoint RLA34P

    Door seals ok , light goes off . This hasn’t got exposed evaporator the stat capillary goes down a tube within the insulation and goes in fairly easily to the same depth as original . Any more suggestions please .
    Thanks for all help so far .
    Geoff.

    #248520
    admin
    Keymaster

    Re: Hotpoint RLA34P

    Hi

    It sounds like the evaperator phile mounting has come off the evaperator which is unable to be repaired.

    How old is the appliance ?

    If only a couple of years or so then so as every one else is doing and demand not fit for purpose and get a new one.

    Bryan