    Got a problem with this one, Delicate + Fast lights coming on towards the end of the wash and the book shows it a Heater circuit Fault. Trouble is the heater is working, In fact If anything its overheating as the water temp on the 40c wash seemed a bit high to me. Have changed the PCB and now its doing the 40c wash OK but faulting on the hotter washes.
    Running out of ideas now.

    Goose

    #249598
    hotpnt
    Participant

    Re: Hotpoint FDW60

    is there any earth leakage from the heater?

    #249599
    goosegreen
    Participant

    Re: Hotpoint FDW60

    Didn’t try that as the house has a RCD, But will call again to check. I was thinking this morning that I should have checked for earth leakage as the heaters are prone to failure.


    Goose

    #249600
    goosegreen
    Participant

    Re: Hotpoint FDW60

    Called back today Heater meggas out OK, Running of ideas now.Is there just one other safety stat on this model?


    Goose

    #249601
    goosegreen
    Participant

    Re: Hotpoint FDW60

    Called again today for one last look before I called it a day, But still none the wiser. Other than that the pcb I fitted had the same fault as the original ie overheating completely stumped.