Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Zanussi fs1255w Module
- This topic has 12 replies, 5 voices, and was last updated 17 years, 11 months ago by
allan.
-
AuthorPosts
-
April 18, 2008 at 4:40 pm #36127
allan
ParticipantHi can anyone please tell me what the difference is, on connects site there are two different modules listed for the Zanussi fs1255w one is preconfigured and about £40 more? I have ordered the cheaper one and think i may have made a cock up!
Thanks AllanApril 18, 2008 at 5:52 pm #249664boselecta
ParticipantRe: Zanussi fs1255w Module
One is the pre-configured, the other you have to configure yourself using binary coding, can be quite trickey to do. Did a day course on coding these modules from blank at last place of work, I would advise getting the pre-configured board. i have the config codes if you are going to do it yourself.
what is the pnc?, its easier to do on machines that have an led display.April 18, 2008 at 7:07 pm #249665allan
ParticipantRe: Zanussi fs1255w Module
hi that would help a lot thanks, i have already got new board so will have to try and program it 😥 I think the pcn is 914791166 serial no. 32100949 type p6847646
Thanks again, look for ward to receiving the codes
AllanApril 18, 2008 at 8:43 pm #249666boselecta
ParticipantRe: Zanussi fs1255w Module
will post it tomoro when back in the office
April 18, 2008 at 8:45 pm #249667allan
ParticipantRe: Zanussi fs1255w Module
Cheers mate
April 18, 2008 at 8:56 pm #249668helo_75
Participantits written on the pcb
on the white label on the top
good luck
April 19, 2008 at 12:10 pm #249669boselecta
ParticipantRe: Zanussi fs1255w Module
Sorry to get your hopes up havn’t got his config code, too late model. you will need a pre-configured board as these blank ones reply on you having the code. try electrolux tech to get the code.
The code wont be on the top of a blank board.April 19, 2008 at 12:22 pm #249670allan
ParticipantRe: Zanussi fs1255w Module
Thanks for your help and time
AllanApril 19, 2008 at 12:55 pm #249671Seamy
ParticipantRe: Zanussi fs1255w Module
As Helo stated, code for new board will have to be copied off old one and new board then configured, theres a white sticker on old board with the code written on it.
Its not that easy to do if you haven’t done it before.April 19, 2008 at 1:02 pm #249672DentedPorsche
ParticipantRe: Zanussi fs1255w Module
Can you program the EWM1000 boards? There are no instructions in the service manual for it (that I can see) and if I remember correctly there isn’t a code sticker on the old module either.
There’s no code on my TDS disc and there’s no code on Pro Corner either.
I’m interested in this one as I’ve always been given pre configured boards.Brian
April 19, 2008 at 1:04 pm #249673allan
ParticipantRe: Zanussi fs1255w Module
Thanks, how can you enter the code and then configure the board?
Thanks AllanApril 19, 2008 at 1:09 pm #249674helo_75
Participantahhhh, nope,you cant configure ewm1000 pcb’s
u need a configured on for that, im afraid
April 19, 2008 at 1:25 pm #249675Seamy
ParticipantRe: Zanussi fs1255w Module
132120226 or 1324017209 are listed as non configured boards for this machine.
97391479116607 is the configured board.
Electrolux now only supply the configured type, presume other suppliers still have old stocks of non configured boards.Not sure how to configure this board type but as far as i’m aware all new boards have a serial interface connection point (J7 on this board) & in future Service Force engineers will be able to reconfigure all boards using a laptop and SideKick software.
😳 -
AuthorPosts