Hi, I have a fault with a F&P GW703. the inlet valve(s) give very short pulses, and after a short time it just stops and starts beeping. I’ve gone into the diagnostic mode as per the sticky and read a fault of 10000100. This unit has the green control board. Any ideas appreciated.
Fault code 132 Single Current trip
Youwould have to check connections To rotor postion sensor(RPS)
There are numerous threads relating to this error
Have to check for corroed terminals Etc
Would suggest being a machine of this age to check for leaks around the Shaft area Typically water leaks down onto to motor & RPS causing these faults Not good news im afraid