    Participant

    All I seem to get at the moment is either these or the Diplomat variant with weird faults and no code.
    This one is beeping twice and trying to start (ie drain) for a second, then dead for three seconds, then same again ad infinitum.
    They have reported door sticking and the facia needs replacing (lugs at top of lock unit broken) but I can’t see that causing this fault.
    Reset the board and the same fault happens when you select the reset rinse prog.
    Anyone had a similar fault 😕

    TC

    #253097
    cornwell40
    Participant

    Re: Smeg DWI612c

    😳
    Done search with 612c instead of 612G now.

    TC

    #253098
    Penguin45
    Participant

    Re: Smeg DWI612c

    Check mains suppressor, dispenser solenoid. Probably borked PCB.

    Chris.

    #253099
    eastlmark
    Moderator

    Re: Smeg DWI612c

    classic dispenser coil failure symptoms.

    #253100
    cornwell40
    Participant

    Re: Smeg DWI612c

    Aye!!
    Once I checked the search with the right model number, I realised I’d posted this query before.
    For the same customer two years ago when I changed the dispenser and the board 😳 .
    File this one under Berk.