Hotpoint RF60P too cold in fridge

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint RF60P too cold in fridge

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #38586
    Simon46
    Participant

    This conventional one has two stats. Does the freezer stat just operate the high temp warning light? Or does it run the freezer even though the fridge has stopped asking for the compressor to come on?

    S.

    #259347
    Dales-Electronic
    Moderator

    Re: Hotpoint RF60P too cold in fridge

    Normally, the stat in the fridge controls the refrigeration operation and the one bolted to the back just switches the warning light on/off. Change the fridge stat for a VT9 and all should be in order.

    #259348
    Simon46
    Participant

    Re: Hotpoint RF60P too cold in fridge

    Ta Dales.

    S.

    #259349
    Simon46
    Participant

    Re: Hotpoint RF60P too cold in fridge

    This is weird. Stat clicked back on when i was defrosting evaporator with hairdryer. Fitted new stat did not see it go off. 😕

    S.