F&P GW708U No start

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #40706
    daw
    Participant

    The machine performs all normal pre start functions but when the start button is pressed there is no action. I have read with interest many threads and have performed the diagnostic test. I ended up with two different codes relating to the solenoid valves (49 & 50). During the diagnostic test I pressed a few other buttons and was able to get the solenoids working, both hot and cold, as well as the pump. I have pulled the boards out and there appears to be no damage but I haven’t gone over it with a meter.
    I hope the very knowledgeable out there can assist. Cheers

    #267298
    Penguin45
    Participant

    Re: F&P GW708U No start

    49 + 50 refer to the cold and hot valves respectively – wiring is the most likely suspect (oxidisation seems to be a regular issue – clean all contacts and terminals). Check the valve coils for resistance as good practice.

    No start is all too often related to the lid switch and the out of balance switch – top deck off to check.

    Penguin45.