Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Diplomat ADP8322 No wash sympton
- This topic has 10 replies, 4 voices, and was last updated 17 years, 3 months ago by
mrhuggy.
-
AuthorPosts
-
January 5, 2009 at 6:41 pm #42299
mrhuggy
ParticipantThe dishwasher fills but when it should start washing the PCB beeps and the dishwasher drains. Is there an overfill fault causing the pump to operate? I have tried a new PCB to no avail
January 5, 2009 at 8:48 pm #273029lerch
ParticipantRe: Diplomat ADP8322 No wash sympton
Open the door just when the pump kicks in to see how much water you have in. Is there water in the base causing anti-flood to start??
January 5, 2009 at 9:08 pm #273030mrhuggy
ParticipantRe: Diplomat ADP8322 No wash sympton
lerch wrote:Open the door just when the pump kicks in to see how much water you have in. Is there water in the base causing anti-flood to start??
If it is overfilling,what could be the cause,is there a blockage and if so where? Thanks
January 5, 2009 at 9:12 pm #273031lerch
ParticipantRe: Diplomat ADP8322 No wash sympton
Blockage could be in metering tank or pressure switch failure / water in pipe if switch has dropped from correct position.
January 5, 2009 at 9:18 pm #273032aqualectric
ParticipantRe: Diplomat ADP8322 No wash sympton
It’s a Whirlpool machine. One beep then abort is usually NTC failure.
Steve.
January 5, 2009 at 9:19 pm #273033lerch
ParticipantRe: Diplomat ADP8322 No wash sympton
I could stand corrected lol. 😳
January 5, 2009 at 9:39 pm #273034mrhuggy
ParticipantRe: Diplomat ADP8322 No wash sympton
aqualectric wrote:It’s a Whirlpool machine. One beep then abort is usually NTC failure.
Steve. It keeps beeping have tried a ntc. Thanks
January 5, 2009 at 9:41 pm #273035mrhuggy
ParticipantRe: Diplomat ADP8322 No wash sympton
lerch wrote:Blockage could be in metering tank or pressure switch failure / water in pipe if switch has dropped from correct position.
I have not had much experience of this model,where is pressure switch located? Thanks
January 5, 2009 at 9:55 pm #273036aqualectric
ParticipantRe: Diplomat ADP8322 No wash sympton
Pressure switch is in the sump on the right. Remove the filter and you will see a black circular “grid” shaped item. Before you condemn it, clean it thoroughly with a toothbrush. They often get gunked up and malfunction.
It is accessed from underneath and is a twist fit in the sump.HTH,
Steve.
January 5, 2009 at 11:00 pm #273037mrhuggy
ParticipantThanks for that
January 6, 2009 at 7:43 pm #273038Jonah
ParticipantRe: Diplomat ADP8322 No wash sympton
Changed one today, will be the pressure switch gunked up, this one was solid with grease/fat couldnt clean it, F4 fault will flash up.
-
AuthorPosts
- You must be logged in to reply to this topic.