miele T230C

Viewing 9 posts - 1 through 9 (of 9 total)
  • Author
    Posts
  • #43075
    machineman
    Participant

    Why would the safety stat pop on one of these/filters all clean m

    #275966
    electrofix
    Moderator

    Re: meile T230C

    all dryers work on one of two systems

    you either blow the air into the dryer or blow it out

    i think the miele blows it out causing a vacuum in the drum that suck the air in across the elements. in this case if the front or rear seals let air in it does not go through elements and blows trips

    hope this helps

    Dave

    #275967
    presser
    Participant

    Re: meile T230C

    Door opened whilst still heating?

    #275968
    chezza
    Participant

    Re: meile T230C

    sticking contacts on the heater relays , used to be a problem ?

    #275969
    machineman
    Participant

    is there a non gen stat or does anyone know the temp setting the cost with electrue is over the top at £13 m

    #275970
    clayside
    Participant

    Re: meile T230C

    Have had fan impeller full of fluff & rubbish cause poor air flow on these
    clayside

    #275971
    russell555
    Participant

    machineman wrote:is there a non gen stat or does anyone know the temp setting the cost with electrue is over the top at £13 m

    130 stat.. if is is the yellow top one… 140 if its the white

    #275972
    kevinlewis
    Participant

    Re: meile T230C

    i presume you mean the stat in the element box? has been known to be caused when the drum is stationary and the element remains on and overheats. in some cases even the pcb had to be changed to an updated version that shuts the heater off during the drum reversal.

    #275973
    machineman
    Participant

    thanks for the replys will order gen stat i think m