Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #43362
    robbo1973
    Participant

    been here today for not drying got it out half way as major fitting issues going back next week when better accessible.I was hoping for an o/load popped or something but when set on dry the fan kicks in but no heat theo/load stat has live to all 4 connectors and the heater has live to both sides so i am a neutral missing is there a common break in wire on these or is it fed from the board?
    any advice appreciated

    cheers chris.

    #276964
    eastlmark
    Moderator

    Re: SMEG WDI12C

    assuming there is no wiring breakages, then have to suspect the pcb down the bottom, poss dry joint I guess. Some of these had incorrect pcb’s fitted from new but I guess it has worked up to now so that shouldnt be an issue.
    Any error code showing?

    #276965
    robbo1973
    Participant

    Re: SMEG WDI12C

    thanks for reply there is no error code showing and i checked as best i could for broken wires but could only get it out halfway due to bad fitting.

    #276966
    eastlmark
    Moderator

    Re: SMEG WDI12C

    front panel comes off on that one. IIRC only need to access the 2 screws on the side of the facia which means it only needs to be pulled out slightly. Can acces the module that way.

    #276967
    robbo1973
    Participant

    Re: SMEG WDI12C

    cheers mark do you do much work on smeg as i have a part enquiry in trade spares if you can help on that one if not i am gonna ring smeg in the morning as electrue have no record of the model.

    cheers chris

Viewing 5 posts - 1 through 5 (of 5 total)