Hoover HWD120 – 80 washer drier. No. 31001037 0520 0281.
The usual fault with Candy washer driers – condenser pipe ruptures; water everywhere. Annoying but not serious.
Until……..the factory forgot to fit the water splash guard on the lower PCB and it got drenched. The result is a machine that will not programme. Switch on, set to program, press the start button and it stays on “Stop” but the door locks. 😕
Both the lower board and the main PCB look fine, I’ve cleaned the connections and refitted the plugs; still dead.
I am thinking main PCB: but what does the small lower PCB do? If it got water damaged would the main PCB be affected?
I also cannot find the part number for the main PCB.
Any help please!!
Thanks,
Steve.