Zan E40 not interlock

Viewing 10 posts - 1 through 10 (of 10 total)
  • Author
    Posts
  • #43922
    pmb
    Participant

    Hi i have a zanussi IZ16S which is showing e42 through the diagnostics. I have replaced interlock (4 times) and pcb. I have checked all the wiring from interlock which goes to the pcb, pressure swich and on/off switch. I nipped all the connections to make sure they are a tight fit. I checked for earth leaks too on heater and motor. Also i have tightened connections for display module but i still have this problem. The interlock does lock by the way but it continues clicking. Any help on this would be greatly appreciated :lesson:
    Thanks Peter

    #279082
    pmb
    Participant

    Re: Zan E40 not interlock

    Has no one else had this problem? There must be a genius from zanussi that can help, this machine is driving me crazy :bang:
    Thanks Peter

    #279083

    Re: Zan E40 not interlock

    Could door striker not be engaging fully with interlock? What happens when interlock operated manually?
    Mike.

    #279084
    pmb
    Participant

    Re: Zan E40 not interlock

    Thanks Mike but i have tried operating it with a screwdriver but it is the same, it locks but then continues clicking and then shows e40. Does anyone know if zanussi has a technical support number?

    #279085
    Martin
    Participant

    Re: Zan E40 not interlock

    pmb wrote:Does anyone know if zanussi has a technical support number?

    I don’t believe they have but if you have a chat with your local friendly Service Force dealer chances are they’d help you out. I have 3 such dealers in my patch and they have been very cooperative to me over the years. 🙂

    Tip: Best to ring mid afternoon with queries as often as not one of their engineers is back in the office to advise. 😉

    #279086
    Steven
    Participant

    Re: Zan E40 not interlock

    Possible one of the pumps shorted out,usually the recirc, this can damage the triacs on the pcb. You say you have changed the pcb, check the individual triacs you may see one with a chip out of it, trace it back to the relevant pump.
    You may have have damaged the new board.

    Hope this helps

    Steven

    #279087
    boselecta
    Participant

    I recently changed an interlock when it was just clicking like this, when I investigated further turns out the carbon brushes were worn. Replaced them and it worked ok.
    Check for earth leakages.

    #279088
    pmb
    Participant

    Re: Zan E40 not interlock

    Thanks alot everyone for all the advice i am going to get stuck in to this today 😀

    #279089
    Tubs
    Participant

    Re: Zan E40 not interlock

    Steven wrote:Possible one of the pumps shorted out,usually the recirc, this can damage the triacs on the pcb. You say you have changed the pcb, check the individual triacs you may see one with a chip out of it, trace it back to the relevant pump.
    You may have have damaged the new board.

    Hope this helps

    Steven

    Have also had this and was re circ pump melted, had me scratching head for a while.

    #279090
    pmb
    Participant

    Re: Zan E40 not interlock

    It was the wires on the connectors to pressure switch,
    It was intermittent, so several times i thought i solved it.
    Thanks everyone for your input

Viewing 10 posts - 1 through 10 (of 10 total)