Hotpoint drier Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hotpoint drier This topic has 8 replies, 5 voices, and was last updated 17 years ago by waters. Viewing 9 posts - 1 through 9 (of 9 total) Author Posts March 21, 2009 at 6:43 pm #44429 watersParticipant CTD80 gives error code F13.White spot thermostats replaced but still no heat and f13 March 21, 2009 at 7:59 pm #280946 Specialist01269Participant Re: Hotpoint drier Hi: You replaced the stats & obviously checked the element for continuity. Have you replaced the NTC & checked the wiring back to the board? Andy. March 21, 2009 at 8:04 pm #280947 watersParticipant Re: Hotpoint drier It only has the 2 thermostats and the heater.There is no ntc in the middle March 21, 2009 at 8:57 pm #280948 helo_75Participant then put a new heater in with s on it its an ntc problem March 22, 2009 at 8:43 am #280949 MartinParticipant Re: Hotpoint drier waters wrote:It only has the 2 thermostats and the heater.There is no ntc in the middle What’s the serial no of the machine?…and I’ll give you the correct part no for the heater assy you need. 🙂 March 22, 2009 at 12:59 pm #280950 watersParticipant Re: Hotpoint drier SN 510070212 9531357000 March 28, 2009 at 6:30 pm #280951 watersParticipant Re: Hotpoint drier do i replace the heater with the same with 2 stats or the one with 3 March 28, 2009 at 7:35 pm #280952 helo_75Participant doesnt matter, but your supposed to put the one with 3 on March 31, 2009 at 7:37 pm #280953 johnnyjParticipant Re: Hotpoint drier As Helo says change the heater, if the heater and stats have had a good soaking you will get various thermistor faults, i’ve had a few recalls just fitting the stats trying to keep the cost down only to go back and fit a heater assy, JJ Author Posts Viewing 9 posts - 1 through 9 (of 9 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In